NO | Technical requirement | Technical parameter | Remarks |
1 | 设备内腔表面粗糙度/Surface roughness of the inner cavity of equipment | Ra≤0.5um | |
2 | 无菌传递总时间/Total time of aseptic transfer | 100-120min | The full load |
3 | 除湿总时间/Total dehumidification time | 30-45min | |
4 | 灭菌总时间/Total sterilization time | 30-45min | |
5 | 通风总时间/Total ventilation time | 60-90min | |
6 | 灭菌浓度/Sterilizing concentration | 150-400PPM | |
7 | 灭菌后残留VHP浓度标准/Standard of residual VHP concentration after sterilization | ≤1ppm | |
8 | 内腔材质/Inner cavity material | SUS304/T2.0mm | |
9 | 设备外表面材质/External surface material of equipment | SUS304 | |
10 | 换气次数/Air change times | 150-200pcs | |
11 | 设备运行阶段内部洁净等级/Internal cleanliness grade of equipment operation stage | A级 | |
12 | 设备泄露率/Equipment leakage rate | ≤0.5% | |
13 | 噪声级别/Noise level | ≤75db | |
14 | 灭菌效果/Sterilization effect | 6LOG | |
15 | 总功率(W)/Total power (W) | ≤3500W | |
16 | 非金属材料/Nonmetallic materials | (PTFE)、Silica gel、Tempered glass | |
17 | 汽化温度/Vaporization temperature | ≤100℃ | |
18 | 重量/Weight | 600KG | |