The analogue transmitters of the PR1591 series from Sartorius have been especially designed for use in industrial environment, and are particularly suited for applications with hazardous areas (zone 1) like chemical, petrochemical and food industries. The applications range from level control and simple weighing to complex applications e.g. mixing and filling stations, in conjunction with PLCs, computers or other supervisory systems.
Weight transmitter PR 1590/24 PR 1591/00 PR 1591/10
Accuracy class 0.05 % 0.1 % 0.1 %
Linearity 0.01 % 0.01 % 0.01 %
Zero stability 0.09 % / 10 K < 0.17 % / 10 K < 0.17 % / 10 K
Span stability 0.05 % / 10 K < 0.10 % / 10 K < 0.10 % / 10 K
Ranges span 2.5–25 mV 2.5–25 mV 2.5–25 mV
Ranges deadload 0–15 mV 0–15 mV 0–15 mV
Load cell supply 12 V 12 V 12 V
Minimum impedance 75 O 100 O 100 O
(resulting)
Supply voltage 24 VDC/AC 110/128/220/238 VAC 110/128/220/238 VAC
(nominal) ± 15 VDC
Voltage tolerances DC: 18 … 33 V -15 % … +10 %
(Operating range) AC: 18 … 28 V 48 Hz to 62 Hz
Power consumption 7.5 W / 11 VA 11 W max. / 20 VA max.
(at nominal voltage)
Isolated output yes
(signal / supply)
Control outputs no 2 relays 2 relays
Additional features Display built-in
Net weight 0.23 kg 2.6 kg 2.6 kg
Shipping weight 0.50 kg 3.6 kg 3.6 kg
Operating temperat. -10 oC to +55 oC -10 oC to +55 oC 0 oC to +55 oC
Storage temperature -40 oC to +70 oC -20 oC to +60 oC -20 oC to +60 oC
Packing dimensions 240 + 160 + 70 460 + 250 + 220 460 + 250 + 220
订货型号
PR 1590/24: ±15 V or 24 VDC/AC according to NAMUR
PR 1590/66: intrinsically safe version (CENELEC)
PR 1591/00: field housing (IP 65) two relays for setpoints
PR 1591/10: field housing (IP 65) with display two relays for setpoints
PR 1591/60: intrinsically save version (CENELEC), field housing (IP 65) two relays for setpoints