导通测试 |
测量范围 | 20/200/2000Ω (自动量程) |
开路电压 (DC) | 5V±20% (*1) |
短路电路 | 大于200mA |
精确度 | ±0.1Ω (0 - 0.19Ω) ±2%rdg+8dgt (0.2 - 2000Ω) |
绝缘电阻 |
测量范围 | 20/200MΩ (自动量程) | 20/200/2000MΩ (自动量程) |
开路电压(DC) | 250V+25% -0% | 500V+25% -0% | 1000V+20% -0% |
额定电流 | 大于1mA @ 250kΩ | 大于1mA @ 500kΩ | 大于1mA @ 1MΩ |
精确度 | ±2%rdg+6dgt (0 - 19.99MΩ) ±5%rdg+6dgt (20 - 200MΩ) | ±2%rdg+6dgt (0 - 199.9MΩ) ±5%rdg+6dgt (200 - 2000MΩ) |
回路阻抗测试 |
功能 | L-PE | L-PE (ATT) | L-N / L-L |
额定电压 | 100 - 260V 50/60Hz | L-N: 100 - 300V L-L: 300 - 500V 50/60Hz |
额定测试电流 (*2) | 20Ω: 6A/20ms 200Ω: 2A/20ms 2000Ω: 15mA/500ms | L-N: 6A/60ms N-PE: 10mA/约 5s | 20Ω: 6A/20ms |
测量范围 | 20/200/2000Ω (自动量程) | 20/200/2000Ω (自动量程) (L-N < 20ω)=""> | 20Ω |
精确度 | ±3%rdg+4dgt(*3) ±3%rdg+8dgt(*4) | ±3%rdg+6dgt (*3) ±3%rdg+8dgt(*4) | ±3%rdg+4dgt (*3) ±3%rdg+8dgt(*4) |
PSC (L-N / L-L) / PFC (L-PE) |
功能 | PSC | PFC | PFC (ATT) |
额定电压 | 100 - 500V 50/60Hz | 100 - 260V 50/60Hz | |
额定测试电流 (*5) | 6A/20ms | 6A/20ms 2A/20ms 15mA/500ms | L-N: 6A/60ms N-PE: 10mA/approx. 5s |
测量范围 | 2000A/20kA 自动量程 |
精确度 | PSC / PFC 精度是由测量的回路阻抗规格和测量电压规格得到的 |
RCD |
功能 | X1/2 | X1 | X5 | Ramp | 自动 |
跳脱电流设置 | 10/30/100/300/ 500/1000mA | 10/30/ 100mA | 10/30/ 100/300/ 500mA | 取决于每个功能的精确度 测量顺序: X1/2 0°→X1/2 180° →X1 0°→X1 180° →X5 0°→X5 180° 对于额定电流为100mA 或以上的RCD,不使用x5 进行测量. |
跳脱电流时间 | 2000ms | G: 550ms S: 1000ms | 410ms | 从20%到110% 上升了10% G:300ms/ S:500ms X10 times |
额定电压 | 230V+10%-15% 50/60Hz |
精确度 | AC:-8% - -2% A:-10% - 0% | AC: +2% - +8% A: 0% - +10% | AC: ±4% A: ±10% |
Trip time: ±1%rdg+3dgt |
RCD (Uc) |
功能 | UC |
额定电压 | 230V+10% - 15% 50/60Hz |
测量范围 | 100.0V |
测试电流 | ≤ 1/2IΔn (150mA) |
精确度 | +5% - +15%rdg, ±8dgt |
接地电阻测试 |
测量范围 | 20/200/2000Ω 自动量程 |
精确度 | 20Ω: ±3%rdg+0.1Ω 200/2000Ω: ±3%rdg+3dgt (辅助接地电阻 100±5%) |
相位旋转 |
额定电压 | 50-500V 50/60Hz |
备注 | 正确的相位: 显示 "1.2.3" 和 循环标志 反相序列"3.2.1" 和 循环标志 |
工作电压 |
功能 | 工作电压 | 频率 |
额定电压 | 25 - 500V, 45 - 65Hz |
测量范围 | 25 - 500V | 45 - 65Hz |
精确度 | ±2%rdg+4dgt | ±0.5%rdg+2dgt |